agessaman 7b68371a7f feat(alerts): enhance alert test command response for clarity
Improve the response message for the `alert test` command to clarify
that a successful test send does not guarantee automatic alerts are
enabled. This change helps prevent confusion for operators regarding
the status of the alert system after testing.
2026-07-20 19:21:29 -07:00
agessaman f68a0fb9e7 feat(ota): broadcast OTA start/fail milestones on the alert channel
An operator who triggers `ota update` via remote management only sees the
command's reply; the actual OTA runs ~2.5s later and reboots on success,
so the start/fail notifications land outside the reply window. Mirror the
key OTA milestones onto the configured alert channel (in addition to the
Serial log):

- START ("OTA update starting") from beginDeferredOtaUpdate(), i.e. while
  the loop still runs -- a flood queued at the deferred fire could never
  transmit before the flash blocks the loop / reboots on success.
- FAIL ("OTA aborted: ...") at both abort points (teardown barrier
  withheld flashing; preflight/download error).

Success has no message: a successful flash reboots into the new image, so
the node returning on the new version is the signal.

New MyMesh::otaAlert() gates on the `alert on/off` master switch and rides
the configured alert scope (AlertReporter::sendText -> sendChannel ->
resolveAlertScope); no-op when alerts are off or no channel is set. Only
these start/fail milestones -- routine slot connect/disconnect is
unaffected (stays in AlertReporter's fault logic). Documented in ALERTS.md.
Both observer firmwares build.
2026-07-19 07:51:52 -07:00
agessaman c41805d070 Remove detailed fault alert documentation from MQTT_IMPLEMENTATION.md. This change streamlines the file by eliminating extensive sections on fault alerts, including configuration, triggers, and examples, while retaining essential information for clarity and usability. 2026-05-17 21:30:31 -07:00