Payloads of 166 or 167 bytes previously passed the frame-sized bound
(MAX_CHANNEL_DATA_LENGTH = 167) but were rejected by sendGroupData
against MAX_GROUP_DATA_LENGTH (165), causing ERR_CODE_TABLE_FULL (retry
later) to be returned instead of ERR_CODE_ILLEGAL_ARG.
Fixes#3345
- scope the serial config CLI to RP2040; it was exposing the rescue CLI
(cat/rm/erase) on every ESP32 WiFi build, which gates it behind a
physical long-press
- bound and space out RP2040 rejoins: the core's join busy-waits, so cap
it at 5s and retry every 30s instead of every 10s
- stamp the reconnect timer in setup(), so the first loop() doesn't tear
down an association that is still finishing DHCP
- treat stored credentials as a pair, and pass NULL (not "") for an open
network
- teach build_as_lib.py where SerialWifiInterface moved
arduino-pico's WiFi.begin() blocks for up to 2x its 15s timeout, which
stalled the mesh loop on every reconnect attempt; use beginNoBlock().
Log the IP when the link comes up, and the status code when retrying.
Store ssid/pwd in NodePrefs and set them with 'set wifi.ssid' /
'set wifi.pwd' over USB serial; build-time WIFI_SSID/WIFI_PWD stay as
the fallback. Headless WiFi builds get the config CLI on Serial, which
is otherwise unused there.
SerialWifiInterface has no ESP32-specific code, so move it to
helpers/wifi and reuse it on RP2040. Guard the ESP32-only WiFi
event/auto-reconnect calls and poll link state on RP2040 instead.
The serial command buffers must stay NUL-terminated within their
bounds: if they ever aren't, strlen() can return >= sizeof(command)
and the read loop would index past the buffer. Additionally, a full
buffer now becomes a completed line (end-of-line marker placed
inside the buffer, NUL terminator kept) instead of overwriting the
terminator and silently corrupting the buffer for the next pass.
Applies to the serial CLI readers of the repeater, room server,
sensor and secure chat examples, and to the CLI rescue reader of
the companion example.
* Add tz_offset companion prefs and get/set commands for companion cli
* Use tz_offset for clock on display
Signed-off-by: Aleksei Mamlin <mamlinav@gmail.com>
MAX_CLIENTS is defined in both src/helpers/ClientACL.h and examples/simple_repeater/MyMesh.h. Appears it was centralised in the former header file some time ago. Both are included in some places and, depending on which order they're in, either value can win.
This change drops the duplicate entry from the repeater firmware and bumps the central limit up to 32 (per the original repeater firmware value).
Changes:
- Remove MAX_CLIENTS from repeater MyMesh.h
- Increase MAX_CLIENTS limit in ClientACL.h to 32
Boards without a charge-complete signal only infer "full" from voltage, and
a real pack rarely reads the full BATT_MAX_MILLIVOLTS (4.2V), so the plug icon
was effectively never shown. Treat "full" as a high band (>= 95%) so the plug
appears when the battery is charged rather than requiring an exact 100%.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Show a small lightning-bolt icon to the left of the battery indicator on
the ui-new home screen while the device is externally powered, and a plug
icon once the battery reads full. The bolt/plug sits beside the battery so
the fill bar stays clean and uninterrupted. When a buzzer is present, the
mute icon shifts one slot further left so the two never overlap.
Charging state is derived from board.isExternalPowered(), so this works on
any board that reports external power (e.g. the nRF52 VBUS-detect path).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
thinknode_m8: initial support
adds some functionalities to ui_task and epddisplay:
epd display,
- supports screen off, and clear screen
- supports forcing full refresh every N partial refreshes (off by default, configured to 60 for M8)
ui_task
- UI_SHOW_CLOCK flag to display clock on first screen
- rotary button can act like joystick (with regards to Enter key), defaults to old config for existing nodes
- screen off on long press when using rotary button (very handy for the watch)