efiten e7376f0990 rf: re-arm the sampler at the moving cadence when moving again
While parked the next RF sample is armed 5 minutes out. On 'moving again' that timer kept
running, so the first minutes of a drive had no samples (4 min 19 s in a 2026-11-11 log,
20:20:28 to 20:24:47). setPaused(false) now re-arms it at 15 s when it was due later.

Release v1.24.5, SW cache v65.
2026-11-11 20:43:07 +01:00
efiten 156757a853 feat: RF environment sampler with moving/parked cadence 2026-08-18 11:05:54 +02:00
efiten 8c46a31c50 feat: parse companion radio stats frames 2026-08-18 11:00:45 +02:00