The 2026-09-13 log ends with two and a half minutes of "discover send failed: GATT
Server is disconnected" — one sweep every 30 seconds, each a write into a characteristic
that no longer exists — an "rf sample incomplete — discarded" for every sampler round,
and region asks failing the same way. None of it could reach a radio.

discoverDecision takes linkUp and reports 'link-down' ahead of every other state; the
monitor tick returns right after rendering it, the RF sampler reschedules without
sampling, and region asks stop with them. The discover clock is not advanced while down,
so the first tick after the link returns sweeps immediately instead of waiting out an
interval.

The link state is read from the browser's own device object through a new
transport.connected(), not mirrored into a flag of ours. A flag would be stale exactly
when it matters, which is the same failure shape as the duplicated default fixed in
v1.17.1 — one source per fact.

Said once in each direction rather than per tick. A log that just goes quiet is
indistinguishable from a crash, an area with nothing to hear, or a feature switched off.

Capture, queueing and uploading are untouched: receptions already in hand are still
queued and published, and the MQTT link keeps its own reconnect.