Files
livekit/pkg
Yeongbin Jeong 246639c5fe sfu: measure probe timing against mono.Now() (#5247)
The probe controller, the probe packet group and the probe cluster store
mono.Now() timestamps, but measure the time since them with time.Since.
Since livekit/protocol#1439, mono.Now() has no monotonic reading, so
time.Since takes the difference from the wall clock. After the wall
clock steps, for example on an NTP correction, the settle wait and the
probe pacing are off by the step for the rest of the process's life.

Use mono.Now().Sub instead.
2026-11-20 14:09:12 +05:30
..
2025-11-28 21:51:53 +05:30