Yeongbin Jeong 4951b4c401 sfu: return the last receiver report time in the wall clock domain (#5248)
DownTrack.GetPrimaryStreamLastReceiverReportTime returned
time.Unix(0, LastReceiverReportTime()), but that is a mono timestamp,
not a real wall time. Connection quality compares it with time.Now()
and with the streaming start, which is a wall time. After the wall clock
steps, for example on an NTP correction, a receiver report looks older
or newer than it is by the step, so the scorer can mark a down track
POOR after one update without a report, or miss reports that stopped.

Convert the mono timestamp to wall time, and return zero time before the
first receiver report, as #5006 does for the last sender report time.