Eliminates the SQLITE_BUSY VACUUM bug from #1283 by making cmd/server truly read-only. The bug surfaced when supervisord launched both ingestor + server in one container: the ingestor took the write lock for INSERTs, then the server's VACUUM-on-startup immediately failed with SQLITE_BUSY. Same race latently affected three other server-side writes. Four write operations moved out of cmd/server/: 1. VACUUM / auto_vacuum migration (cmd/server/vacuum.go, entire file) → cmd/ingestor/db.go Store.CheckAutoVacuum (already existed; ingestor runs it BEFORE the MQTT subscriber starts so there is no contention with concurrent writes). 2. PruneOldPackets (DELETE FROM transmissions) cmd/server/db.go → cmd/ingestor/maintenance.go (new file, Store.PruneOldPackets) + main.go scheduler. 3. PruneOldMetrics (DELETE FROM observer_metrics) cmd/server/db.go → cmd/ingestor/db.go Store.PruneOldMetrics (already existed). 4. RemoveStaleObservers (UPDATE observers SET inactive = 1) cmd/server/db.go → cmd/ingestor/db.go Store.RemoveStaleObservers (already existed). Server-side changes: - vacuum.go deleted; checkAutoVacuum / runIncrementalVacuum gone. - cmd/server/db.go: PruneOldPackets, PruneOldMetrics, RemoveStaleObservers deleted. - cmd/server/main.go: packet/metrics/observer prune schedulers removed; the neighbor-edge prune scheduler (PruneNeighborEdges) is intentionally left in place — outside scope of #1283, tracked separately. - routes.go + openapi.go: /api/admin/prune endpoint removed (prune is scheduled by the ingestor now; operators restart the ingestor for an ad-hoc pass). Ingestor changes: - New cmd/ingestor/maintenance.go with Store.PruneOldPackets. - cmd/ingestor/config.go gains RetentionConfig.PacketDays and Config.PacketDaysOrZero(). - cmd/ingestor/main.go runs PruneOldPackets at startup (if packetDays > 0) and on a 24h ticker. Docs: - AGENTS.md: documents the read/write separation invariant. - config.example.json: notes that retention + vacuumOnStartup are consumed by the ingestor. TDD: - Red: bb1d749a — invariant tests + Store.PruneOldPackets stub. - Green: this commit — real implementation + server-side removals. Note: cachedRW() still has three out-of-scope callers in cmd/server (neighbor_persist.go, ensure_indexes.go, from_pubkey_migration.go). Those are pre-existing write paths not covered by issue #1283 and are left untouched per the issue scope. Future work can relocate them under the same invariant.
MeshCore MQTT Ingestor (Go)
Standalone MQTT ingestion service for CoreScope. Connects to MQTT brokers, decodes raw MeshCore packets, and writes to the same SQLite database used by the Node.js web server.
This is the first step of a larger Go rewrite — separating MQTT ingestion from the web server.
Architecture
MQTT Broker(s) → Go Ingestor → SQLite DB ← Node.js Web Server
(this binary) (shared)
- Single static binary — no runtime dependencies, no CGO
- SQLite via
modernc.org/sqlite(pure Go) - MQTT via
github.com/eclipse/paho.mqtt.golang - Runs alongside the Node.js server — they share the DB file
- Does NOT serve HTTP/WebSocket — that stays in Node.js
Build
Requires Go 1.22+.
cd cmd/ingestor
go build -o corescope-ingestor .
Cross-compile for Linux (e.g., for the production VM):
GOOS=linux GOARCH=amd64 go build -o corescope-ingestor .
Run
./corescope-ingestor -config /path/to/config.json
The config file uses the same format as the Node.js config.json. The ingestor reads the mqttSources array (or legacy mqtt object) and dbPath fields.
Environment Variables
| Variable | Description | Default |
|---|---|---|
DB_PATH |
SQLite database path | data/meshcore.db |
MQTT_BROKER |
Single MQTT broker URL (overrides config) | — |
MQTT_TOPIC |
MQTT topic (used with MQTT_BROKER) |
meshcore/# |
CORESCOPE_INGESTOR_STATS |
Path to the per-second stats JSON file consumed by the server's /api/perf/io and /api/perf/write-sources endpoints (#1120) |
/tmp/corescope-ingestor-stats.json |
Stats file (CORESCOPE_INGESTOR_STATS)
Every second the ingestor publishes a JSON snapshot of its counters
(tx_inserted, obs_inserted, walCommits, backfillUpdates.*, etc.) plus
a procIO block sampled from /proc/self/io (read/write/cancelled bytes per
second + syscall counts). The server reads this file and surfaces the data on
the Perf page so operators can self-diagnose write-volume anomalies.
The writer uses O_NOFOLLOW | O_CREAT | O_TRUNC mode 0o600, so a
pre-planted symlink at the path cannot be used to clobber an arbitrary file.
Security note: the default lives in /tmp, which is world-writable on
most hosts (sticky bit only protects deletion, not creation). On
shared/multi-tenant hosts, override CORESCOPE_INGESTOR_STATS to point at a
private directory (e.g. /var/lib/corescope/ingestor-stats.json) that only
the corescope user can write to.
Minimal Config
{
"dbPath": "data/meshcore.db",
"mqttSources": [
{
"name": "local",
"broker": "mqtt://localhost:1883",
"topics": ["meshcore/#"]
}
]
}
Full Config (same as Node.js)
The ingestor reads these fields from the existing config.json:
mqttSources[]— array of MQTT broker connectionsname— display name for loggingbroker— MQTT URL (mqtt://,mqtts://)username/password— auth credentialstopics— array of topic patterns to subscribeiataFilter— optional regional filter
mqtt— legacy single-broker config (auto-converted tomqttSources)dbPath— SQLite DB path (default:data/meshcore.db)
Test
cd cmd/ingestor
go test -v ./...
What It Does
- Connects to configured MQTT brokers with auto-reconnect
- Subscribes to mesh packet topics (e.g.,
meshcore/+/+/packets) - Receives raw hex packets via JSON messages (
{ "raw": "...", "SNR": ..., "RSSI": ... }) - Decodes MeshCore packet headers, paths, and payloads (ported from
decoder.js) - Computes content hashes (path-independent, SHA-256-based)
- Writes to SQLite:
transmissions+observationstables - Upserts
nodesfrom decoded ADVERT packets (with validation) - Upserts
observersfrom MQTT topic metadata
Schema Compatibility
The Go ingestor creates the same v3 schema as the Node.js server:
transmissions— deduplicated by content hashobservations— per-observer sightings withobserver_idx(rowid reference)nodes— mesh nodes discovered from advertsobservers— MQTT feed sources
Both processes can write to the same DB concurrently (SQLite WAL mode).
What's Not Ported (Yet)
- Companion bridge format (Format 2 —
meshcore/advertisement, channel messages, etc.) - Channel key decryption (GRP_TXT encrypted payload decryption)
- WebSocket broadcast to browsers
- In-memory packet store
- Cache invalidation
These stay in the Node.js server for now.
Files
cmd/ingestor/
main.go — entry point, MQTT connect, message handler
decoder.go — MeshCore packet decoder (ported from decoder.js)
decoder_test.go — decoder tests (25 tests, golden fixtures)
db.go — SQLite writer (schema-compatible with db.js)
db_test.go — DB tests (schema validation, insert/upsert, E2E)
config.go — config struct + loader
util.go — shared utilities
go.mod / go.sum — Go module definition