Files
meshcore-bot/meshcore_bot.py
T
agessaman a791b223c7 fix(core): stop on SIGTERM and terminal close when the terminal is gone
The shutdown handler printed before setting its flags. Once the bot's terminal had closed, that print raised OSError and swallowed SIGTERM and SIGINT, leaving a bot that only kill -9 could stop. The flags are now set first and the print is guarded.

SIGHUP was always a config reload, so a bot started from a terminal kept running unattended after the terminal closed. It now shuts down when SIGHUP arrives and the controlling terminal it started with is gone. SIGHUP stays a reload under systemd, launchd, Docker, and nohup, and when sent by hand while the terminal is open.

macOS still opens /dev/tty after a hangup, so the terminal check also does an empty write. I could only verify it on macOS.
2026-11-13 06:47:44 -08:00

410 lines
15 KiB
Python

#!/usr/bin/env python3
"""
MeshCore Bot using the meshcore-cli and meshcore.py packages
Uses a modular structure for command creation and organization
"""
import argparse
import asyncio
import configparser
import contextlib
import json
import os
import signal
import sys
from modules.config_snapshot import config_to_redacted_sections, redacted_sections_to_ini_text
def _has_controlling_terminal() -> bool:
"""True while this process has a usable controlling terminal.
False under systemd, launchd, and Docker without a tty, and also once the
terminal the bot was started from has been closed.
"""
try:
fd = os.open("/dev/tty", os.O_RDWR | os.O_NOCTTY)
except OSError:
return False
try:
# macOS still opens /dev/tty after a hangup; only a write shows it is
# dead. An empty write sends nothing to a live terminal.
os.write(fd, b"")
except OSError:
return False
finally:
os.close(fd)
return True
def _configure_unix_signal_handlers(loop, bot, shutdown_event: asyncio.Event) -> None:
"""Register Unix signal handlers for shutdown and config reload."""
def shutdown_handler():
"""Signal handler for graceful shutdown."""
# asyncio.add_signal_handler replaces SIGINT/SIGTERM handling for the loop; the
# bot's threading.Event + connected flag must be set here too or the main loop
# can run another iteration and restart the web viewer before stop() runs.
# Set the flags before anything that can fail: a print to a closed
# terminal raises OSError, and that used to swallow the signal.
bot._shutdown_event.set()
bot.connected = False
shutdown_event.set()
with contextlib.suppress(OSError, ValueError):
print("\nShutting down...")
def reload_handler():
"""Reload config on SIGHUP without exiting."""
bot.logger.info("Received SIGHUP, reloading configuration...")
success, msg = bot.reload_config()
if success:
bot.logger.info("SIGHUP config reload succeeded: %s", msg)
else:
bot.logger.warning("SIGHUP config reload failed: %s", msg)
# A bot started from a terminal gets SIGHUP when that terminal closes. It
# must exit then, not reload and run on unattended. Under nohup the caller
# asked for the bot to outlive the terminal, so SIGHUP stays a reload.
has_sighup = hasattr(signal, "SIGHUP")
exits_with_terminal = (
has_sighup
and signal.getsignal(signal.SIGHUP) is not signal.SIG_IGN
and _has_controlling_terminal()
)
def hangup_handler():
"""Shut down if SIGHUP means the terminal closed; otherwise reload."""
if exits_with_terminal and not _has_controlling_terminal():
bot.logger.info("Terminal closed (SIGHUP), shutting down...")
shutdown_handler()
else:
reload_handler()
# Register shutdown signals
for sig in (signal.SIGTERM, signal.SIGINT):
loop.add_signal_handler(sig, shutdown_handler)
# Register config reload signal (Unix daemons convention)
if has_sighup:
loop.add_signal_handler(signal.SIGHUP, hangup_handler)
_MAX_CONFIG_ISSUES_SHOWN = 15
def _collect_config_issues(config_path: str) -> list[tuple[str, str]]:
"""Errors and warnings from the config linter; ``[]`` if the linter itself fails.
Imported lazily and guarded so a broken linter can never block startup.
"""
try:
from modules.config_validation import (
SEVERITY_ERROR,
SEVERITY_WARNING,
validate_config,
)
return [
(sev, msg)
for sev, msg in validate_config(config_path)
if sev in (SEVERITY_ERROR, SEVERITY_WARNING)
]
except Exception as exc: # noqa: BLE001 - never block startup on the linter itself
print(f"Config validation skipped: {exc}", file=sys.stderr)
return []
def _report_config_issues(issues: list[tuple[str, str]], logger=None) -> None:
"""Report config-linter findings through *logger*, or stderr when there is none.
A misspelled key is the most common cause of "why doesn't my setting work",
and the linter usually names the intended key. Sending that only to stderr put
it in the journal, where an operator reading the configured log file never saw
it. Prefer the logger so the finding lands in the log; stderr remains the
fallback for the window before the logger exists.
"""
shown = issues[:_MAX_CONFIG_ISSUES_SHOWN]
overflow = len(issues) - len(shown)
def emit(severity: str, text: str) -> None:
if logger is None:
print(text, file=sys.stderr)
elif severity == "error":
logger.error(text)
else:
logger.warning(text)
for severity, message in shown:
emit(severity, f"Config {severity}: {message}")
if overflow > 0:
emit(
"warning",
f"Config: ... and {overflow} more issue(s); "
"run with --validate-config for the full report",
)
def _acquire_instance_lock(config_path: str):
"""Refuse to start when another bot already runs against this database.
Exits 1 when the lock is held. A lock file that cannot be created is only a
warning: the guard must not stop a bot that would otherwise run.
"""
from modules.database_restore import configured_bot_database_path
from modules.instance_lock import InstanceAlreadyRunning, acquire_instance_lock
database_path = configured_bot_database_path(config_path)
if database_path is None:
return None
try:
return acquire_instance_lock(database_path)
except InstanceAlreadyRunning as exc:
holder = f"PID {exc.pid}" if exc.pid is not None else "another process"
print(
f"Error: meshcore-bot is already running against {database_path} ({holder}).",
file=sys.stderr,
)
print(
"Two instances on one radio disconnect each other in a loop. "
"Stop the running instance before starting another.",
file=sys.stderr,
)
sys.exit(1)
except OSError as exc:
print(
f"Warning: could not take the single-instance lock beside {database_path}: {exc}",
file=sys.stderr,
)
return None
def main():
parser = argparse.ArgumentParser(
description="MeshCore Bot - Mesh network bot for MeshCore devices"
)
parser.add_argument(
"--config",
default="config.ini",
help="Path to configuration file (default: config.ini)",
)
parser.add_argument(
"--validate-config",
action="store_true",
help="Validate config section names and exit before starting the bot (exit 1 on errors)",
)
parser.add_argument(
"--show-config",
action="store_true",
help="Print resolved config.ini with sensitive keys redacted and exit",
)
parser.add_argument(
"--show-config-json",
action="store_true",
help="Print resolved config.ini as redacted JSON and exit",
)
args = parser.parse_args()
if args.show_config and args.show_config_json:
print("Error: --show-config and --show-config-json are mutually exclusive", file=sys.stderr)
sys.exit(1)
if args.show_config or args.show_config_json:
cfg = configparser.ConfigParser()
try:
loaded_paths = cfg.read(args.config, encoding="utf-8")
except configparser.Error as exc:
print(f"Error: Invalid config file '{args.config}': {exc}", file=sys.stderr)
sys.exit(1)
if not loaded_paths:
print(f"Error: Config file not found: {args.config}", file=sys.stderr)
sys.exit(1)
sections = config_to_redacted_sections(cfg)
if args.show_config_json:
print(json.dumps(sections, indent=2, sort_keys=True))
else:
print(redacted_sections_to_ini_text(sections))
sys.exit(0)
if args.validate_config:
from modules.config_validation import (
SEVERITY_ERROR,
SEVERITY_WARNING,
validate_config,
)
results = validate_config(args.config)
has_error = False
for severity, message in results:
if severity == SEVERITY_ERROR:
print(f"Error: {message}", file=sys.stderr)
has_error = True
elif severity == SEVERITY_WARNING:
print(f"Warning: {message}", file=sys.stderr)
else:
print(f"Info: {message}", file=sys.stderr)
sys.exit(1 if has_error else 0)
# Always sanity-check the config on normal startup too — misspelled
# sections/keys otherwise fail silently and are the most common source of
# "why doesn't my setting work" confusion. Non-fatal: warn and continue.
# Collected here, before anything opens the database, but reported once the
# bot's logger exists so the findings reach the configured log file.
_config_issues = _collect_config_issues(args.config)
from modules.database_restore import (
DatabaseRestoreError,
apply_pending_restores_from_config,
)
# Taken before a pending restore so a second instance can never replace the
# database under a running bot. Held until the process exits.
try:
_instance_lock = _acquire_instance_lock(args.config) # noqa: F841 - held for process life
except DatabaseRestoreError as exc:
print(f"Error: {exc}", file=sys.stderr)
sys.exit(1)
# A restore requested by the viewer is applied only here, before importing
# and constructing MeshCoreBot (which opens the DB and launches writers).
# The service manager must restart the bot and viewer as one unit.
try:
restore_results = apply_pending_restores_from_config(args.config)
except DatabaseRestoreError as exc:
print(f"Error: pending database restore was not applied: {exc}", file=sys.stderr)
print(
"The active database was left unchanged. Correct or remove the pending restore "
"file before restarting.",
file=sys.stderr,
)
sys.exit(1)
for restore_result in restore_results:
recovery = restore_result.recovery_backup_path
recovery_note = f"; recovery backup: {recovery}" if recovery else ""
print(f"Applied pending database restore: {restore_result.database_path}{recovery_note}")
from modules.core import MeshCoreBot
try:
bot = MeshCoreBot(config_file=args.config)
except Exception:
# No logger to route them through, and a bad config is the likeliest reason
# construction failed, so stderr is both the only channel left and the one
# the operator is about to read.
_report_config_issues(_config_issues)
raise
_report_config_issues(_config_issues, bot.logger)
# Use asyncio.run() which handles KeyboardInterrupt properly
# For SIGTERM, we'll handle it in the async context
async def run_bot():
"""Run bot with proper signal handling.
Returns True when the bot shut down cleanly, or False when it could not
connect to the radio at startup.
"""
loop = asyncio.get_running_loop()
started = True
def meshcore_task_exception_handler(loop, context):
"""Log unhandled exceptions from asyncio tasks (e.g. meshcore reader)."""
exc = context.get('exception')
msg = context.get('message', 'Unhandled exception in task')
if exc is not None:
bot.logger.warning(
"%s: %s",
msg,
exc,
exc_info=(type(exc), exc, exc.__traceback__),
)
else:
bot.logger.warning("%s: %s", msg, context)
loop.set_exception_handler(meshcore_task_exception_handler)
# Set up signal handlers for graceful shutdown (Unix only)
if sys.platform != 'win32':
shutdown_event = asyncio.Event()
bot_task = None
try:
# Register signal handlers
_configure_unix_signal_handlers(loop, bot, shutdown_event)
# Start bot
bot_task = asyncio.create_task(bot.start())
# Wait for shutdown or completion
done, pending = await asyncio.wait(
[bot_task, asyncio.create_task(shutdown_event.wait())],
return_when=asyncio.FIRST_COMPLETED
)
# Cancel pending tasks
for task in pending:
task.cancel()
try:
await task
except asyncio.CancelledError:
pass
# Handle bot task completion
if bot_task:
if shutdown_event.is_set() and not bot_task.done():
# Ensure the bot loop sees shutdown even if the signal handler ordering
# left a race before cancel.
bot._shutdown_event.set()
bot.connected = False
# Shutdown triggered: cancel if still running
bot_task.cancel()
# Always await bot_task to ensure proper cleanup
# This is necessary because:
# 1. If the task completed normally, we need to await to surface exceptions
# 2. If the task was cancelled, it only becomes "done" after being awaited
# (cancellation is not immediate - the task must be awaited for the
# CancelledError to be raised and the task to fully terminate)
try:
started = await bot_task
except asyncio.CancelledError:
# Expected when cancelled, ignore
started = True
finally:
# Always ensure cleanup happens
await bot.stop()
return started
else:
# Windows: just run and catch KeyboardInterrupt
try:
started = await bot.start()
finally:
await bot.stop()
return started
try:
started = asyncio.run(run_bot())
except KeyboardInterrupt:
# Cleanup already handled in run_bot's finally block
print("\nShutdown complete.")
except Exception as e:
# Cleanup already handled in run_bot's finally block. A failure that
# escapes asyncio.run (e.g. BleakError from the BLE adapter) must exit
# non-zero so launchd and the Supervisor watchdog restart the bot.
print(f"Error: {e}")
sys.exit(1)
else:
if not started:
# A startup connection failure must exit non-zero: launchd
# (KeepAlive SuccessfulExit=false) and the Supervisor watchdog only
# restart failed exits, and a zero status reads as an intentional stop.
sys.exit(1)
if __name__ == "__main__":
main()