Files
MeshCore/variants
Alex Beal 0908b03491 Fix: Do not misidentify IMU as an RTC on Heltec T1
The T1 has an ICM-42607-P IMU with the same address as a DS3231 RTC.
This completely breaks the clock on the T1. Reading the time results in
a garbage value, causing all sorts of strange issues. The time never
advances, which breaks logging in to repeaters (due to their time-based
replay protection).

This simply disables the probe on the I2C line. The DS3231 doesn't have
a WHO_AM_I register that could be used to prevent misidentifying it, so
this simpler fix is used.
2026-08-25 15:00:45 -06:00
..
2026-07-06 12:04:42 -04:00
2026-08-18 09:34:34 +02:00