@@ -108,7 +108,7 @@ const BINARY_DISCOVERY_LOOKUP: {[s: string]: KeyValue} = {
|
||||
window_open: {device_class: 'window'},
|
||||
} as const;
|
||||
const NUMERIC_DISCOVERY_LOOKUP: {[s: string]: KeyValue} = {
|
||||
ac_frequency: {device_class: 'frequency', enabled_by_default: false, entity_category: 'diagnostic', state_class: 'measurement'},
|
||||
ac_frequency: {device_class: 'frequency', state_class: 'measurement'},
|
||||
action_duration: {icon: 'mdi:timer', device_class: 'duration'},
|
||||
alarm_humidity_max: {device_class: 'humidity', entity_category: 'config', icon: 'mdi:water-plus'},
|
||||
alarm_humidity_min: {device_class: 'humidity', entity_category: 'config', icon: 'mdi:water-minus'},
|
||||
@@ -140,24 +140,9 @@ const NUMERIC_DISCOVERY_LOOKUP: {[s: string]: KeyValue} = {
|
||||
state_class: 'measurement',
|
||||
},
|
||||
cube_side: {icon: 'mdi:cube'},
|
||||
current: {
|
||||
device_class: 'current',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
current_phase_b: {
|
||||
device_class: 'current',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
current_phase_c: {
|
||||
device_class: 'current',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
current: {device_class: 'current', state_class: 'measurement'},
|
||||
current_phase_b: {device_class: 'current', state_class: 'measurement'},
|
||||
current_phase_c: {device_class: 'current', state_class: 'measurement'},
|
||||
deadzone_temperature: {entity_category: 'config', icon: 'mdi:thermometer'},
|
||||
detection_interval: {icon: 'mdi:timer'},
|
||||
device_temperature: {
|
||||
@@ -244,24 +229,9 @@ const NUMERIC_DISCOVERY_LOOKUP: {[s: string]: KeyValue} = {
|
||||
voc_index: {state_class: 'measurement', icon: 'mdi:molecule'},
|
||||
voc_parts: {device_class: 'volatile_organic_compounds_parts', state_class: 'measurement'},
|
||||
vibration_timeout: {entity_category: 'config', icon: 'mdi:timer'},
|
||||
voltage: {
|
||||
device_class: 'voltage',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
voltage_phase_b: {
|
||||
device_class: 'voltage',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
voltage_phase_c: {
|
||||
device_class: 'voltage',
|
||||
enabled_by_default: false,
|
||||
entity_category: 'diagnostic',
|
||||
state_class: 'measurement',
|
||||
},
|
||||
voltage: {device_class: 'voltage', state_class: 'measurement'},
|
||||
voltage_phase_b: {device_class: 'voltage', state_class: 'measurement'},
|
||||
voltage_phase_c: {device_class: 'voltage', state_class: 'measurement'},
|
||||
water_consumed: {
|
||||
device_class: 'water',
|
||||
state_class: 'total_increasing',
|
||||
|
||||
Reference in New Issue