* Added ecozy Smart Thermostat documentation * Added initial documentation for ecozy and fixed Typo * Fixing doc issues * Fixing doc issues * Update mqtt_topics_and_message_structure.md * Finalizing documentation for ecozy and Bitron thermostats * Update mqtt_topics_and_message_structure.md * Update mqtt_topics_and_message_structure.md
This commit is contained in:
committed by
Koen Kanters
parent
a2ea9c548f
commit
f260bf974b
Binary file not shown.
|
After Width: | Height: | Size: 8.1 KiB |
@@ -185,3 +185,145 @@ Let the device beep.
|
||||
"beep": 5
|
||||
}
|
||||
```
|
||||
|
||||
### eCozy Smart heating thermostat (1TST-EU), Bitron Wireless wall thermostat with relay (AV2010/32)
|
||||
Get local temperature in degrees Celsius (in the range 0x954d to 0x7fff, i.e. -273.15°C to 327.67 ºC)
|
||||
```json
|
||||
{
|
||||
"local_temperature": ""
|
||||
}
|
||||
```
|
||||
|
||||
Get or set offset added to/subtracted from the actual displayed room temperature to NUMBER, in steps of 0.1°C
|
||||
```json
|
||||
{
|
||||
"local_temperature_calibration": "NUMBER" // Possible values: –2.5 to +2.5; leave empty to read
|
||||
}
|
||||
```
|
||||
|
||||
Set temperature display mode
|
||||
```json
|
||||
{
|
||||
"temperature_display_mode": "" // Possible values: 0 to set °C or 1 so set °F
|
||||
}
|
||||
```
|
||||
|
||||
Get room occupancy. Specifies whether the heated/cooled space is occupied or not. If 1, the space is occupied, else it is unoccupied.
|
||||
```json
|
||||
{
|
||||
"thermostat_occupancy": ""
|
||||
}
|
||||
```
|
||||
|
||||
Get or set occupied heating setpoint to NUMBER in degrees Celsius.
|
||||
```json
|
||||
{
|
||||
"occupied_heating_setpoint": "NUMBER" // Possible values: MinHeatSetpointLimit to MaxHeatSetpointLimit, i.e. 7 to 30 by default; leave empty to read
|
||||
}
|
||||
```
|
||||
|
||||
Get or set unoccupied heating setpoint to NUMBER in degrees Celsius
|
||||
```json
|
||||
{
|
||||
"unoccupied_heating_setpoint": "NUMBER" // Possible values: MinHeatSetpointLimit to MaxHeatSetpointLimit, i.e. 7 to 30 by default; leave empty to read
|
||||
}
|
||||
```
|
||||
|
||||
Increase or decrease heating setpoint by NUMBER degrees in °C.
|
||||
```json
|
||||
{
|
||||
"setpoint_raise_lower": {
|
||||
"mode": "0x00", // Possible values: see table below
|
||||
"amount": "NUMBER" // Possible values: signed 8-bit integer that specifies the amount the setpoint(s) are to be increased (or decreased) by, in steps of 0.1°C
|
||||
}
|
||||
}
|
||||
```
|
||||
Attribute Value | Description
|
||||
----------------|-----------------------------------------------
|
||||
0x00 | Heat (adjust Heat Setpoint)
|
||||
0x01 | Cool (adjust Cool Setpoint)
|
||||
0x02 | Both (adjust Heat Setpoint and Cool Setpoint)
|
||||
|
||||
Get or set whether the local temperature, outdoor temperature and occupancy are being sensed by internal sensors or remote networked sensors
|
||||
```json
|
||||
{
|
||||
"remote_sensing": "NUMBER" // Possible values: see table below; leave empty to read
|
||||
}
|
||||
```
|
||||
Bit Number | Description
|
||||
-----------|-----------------------------------------
|
||||
0 | 0 – local temperature sensed internally <br> 1 – local temperature sensed remotely
|
||||
1 | 0 – outdoor temperature sensed internally <br> 1 – outdoor temperature sensed remotely
|
||||
2 | 0 – occupancy sensed internally <br> 1 – occupancy sensed remotely
|
||||
|
||||
Get or set control sequence of operation
|
||||
```json
|
||||
{
|
||||
"control_sequence_of_operation": "NUMBER" // Possible values: see table below; leave empty to read
|
||||
}
|
||||
```
|
||||
Values | Description | Possible Values of SystemMode
|
||||
-------|-----------------------------------------|-------------------------------------
|
||||
0x00 | Cooling Only | Heat and Emergency are not possible
|
||||
0x01 | Cooling With Reheat | Heat and Emergency are not possible
|
||||
0x02 | Heating Only | Cool and precooling are not possible
|
||||
0x03 | Heating With Reheat | Cool and precooling are not possible
|
||||
0x04 | Cooling and Heating 4-pipes | All modes are possible
|
||||
0x05 | Cooling and Heating 4-pipes with Reheat | All modes are possible
|
||||
|
||||
Get or set system mode
|
||||
```json
|
||||
{
|
||||
"system_mode": "NUMBER" // Possible values: see table below; leave empty to read
|
||||
}
|
||||
```
|
||||
Attribute Value | Description
|
||||
----------------|------------------
|
||||
0x00 | Off
|
||||
0x01 | Auto
|
||||
0x03 | Cool
|
||||
0x04 | Heat
|
||||
0x05 | Emergency heating
|
||||
0x06 | Precooling
|
||||
0x07 | Fan only
|
||||
0x08 | Dry
|
||||
0x09 | Sleep
|
||||
|
||||
Get running state
|
||||
```json
|
||||
{
|
||||
"running_state": "" // leave empty when reading
|
||||
}
|
||||
```
|
||||
|
||||
Get or set weekly schedule
|
||||
```json
|
||||
{
|
||||
"weekly_schedule": {
|
||||
"TemperatureSetpointHold": "0x00", // 0x00 setpoint hold off or 0x01 on
|
||||
"TemperatureSetpointHoldDuration": "0xffff", // 0xffff to 0x05a0
|
||||
"ThermostatProgrammingOperationMode": "00xxxxxx" //see table below
|
||||
} // leave empty to read
|
||||
}
|
||||
```
|
||||
Attribute Value | Description
|
||||
----------------|---------------------------------------------------------------------------
|
||||
0 | 0 – Simple/setpoint mode. This mode means the thermostat setpoint is altered only by manual up/down changes at the thermostat or remotely, not by internal schedule programming. <br> 1 – Schedule programming mode. This enables or disables any programmed weekly schedule configurations. <br> Note: It does not clear or delete previous weekly schedule programming configurations.
|
||||
1 | 0 - Auto/recovery mode set to OFF <br> 1 – Auto/recovery mode set to ON
|
||||
2 | 0 – Economy/EnergyStar mode set to OFF <br> 1 – Economy/EnergyStar mode set to ON
|
||||
|
||||
Clear weekly schedule
|
||||
```json
|
||||
{
|
||||
"clear_weekly_schedule": ""
|
||||
}
|
||||
```
|
||||
<!--
|
||||
Coming soon:
|
||||
Get weekly schedule response
|
||||
tz.thermostat_weekly_schedule_rsp
|
||||
Get relay status log
|
||||
tz.thermostat_relay_status_log
|
||||
Get relay status log response
|
||||